BSYXV - UNDISCHARGED BATTERIES/CELLS, MERCURY-ZINC, AX-9/AX-15
- MSDS: BSYXV
- Manufacturer: ALEXANDER MFG CO
- Product Name: UNDISCHARGED BATTERIES/CELLS, MERCURY-ZINC, AX-9/AX-15
- National Stock Number: 6135-00-122-2420
Product Identification
Product ID:UNDISCHARGED BATTERIES/CELLS, MERCURY-ZINC, AX-9/AX-15
MSDS Date:09/20/1991
FSC:6135
NIIN:00-122-2420
MSDS Number: BSYXV
Responsible Party
MASON CITY, ID 50401
US
Emergency Phone: 515-423-1161
Info Phone: 515-423-8955
Preparer: NONE
Cage: 56469
Contractor
Telephone: 631-205-1072
Cage: 0BSY9
Ingredients
MERCURIC OXIDE (SARA III)
CAS: 21908-53-2
RTECS: OW8750000
Fraction By Weight: 45-50%
OSHA PEL 0.1 MG HG/M3;SKIN;C
ACGIH TLV: 0.1 MG HG/M3;S, 9394
MANGANESE DIOXIDE
CAS: 1313-13-9
RTECS: OP0350000
Fraction By Weight: 4-6%
OSHA PEL 5 MG MN/M3 CEILING
ACGIH TLV: 5 MG/M3 (MN DUST) 94
POTASSIUM HYDROXIDE (SARA III)
CAS: 1310-58-3
RTECS: TT2100000
Fraction By Weight: 1-5%
OSHA PEL C, 2 MG/M3
ACGIH TLV: C 2 MG/M3; 9394
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
ZINC (SARA III)
CAS: 7440-66-6
RTECS: ZG8600000
Fraction By Weight: 12-18%
OSHA PEL 10 MG ZNO/M3 TDUST
ACGIH TLV: 10MG ZNO/M3;TDUST 94
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
ZINC OXIDE
CAS: 1314-13-2
RTECS: ZH4810000
Fraction By Weight: 0.1-0.3%
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10MG/M3 TDUST; 9394
GRAPHITE
Fraction By Weight: 2-6%
OSHA PEL 2.5 MG/M3 RDUST
ACGIH TLV: 2 MG/M3 RDUST; 9394
CARBOXY METHYL CELLULOSE (CMC)
Fraction By Weight: .05-.15%
Hazards
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE/CHRONIC: NO HEALTH HAZARDS
LIKELY UNDER PROPER USE.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:RESPIRATORY AND SKIN IRRITATION.
Medical Cond Aggravated by Exposure:RESPIRATORY AND SKIN DISEASE.
First Aid
First Aid:EYES: FLUSH WITH LARGE AMOUNTS OF WATER. IF SYMPTOMS
PERSISTS, GET MEDICAL ATTENTION. SKIN: WASH AREA WITH SOAP AND
WATER. IF SYMPTOMS PERSISTS, GET MEDICAL ATTENTION. INHALATION:
MOVE TO FRESH AIR. A PPLY CPR IF NEEDED. GET MEDICAL ATTENTION.
INGESTION: GET MEDICAL ATTENTION.
Fire Fighting
Extinguishing Media:DRY CHEMICAL.
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE SELF-CONTAINED
BREATHING APPARATUS IF BATTERIES ARE ON FIRE.
Unusual Fire/Explosion Hazard:NONE KNOWN.
Accidental Release
Spill Release Procedures:USE RUBBER GLOVES FOR CLEANING UP SPILLS OR
HANDLING INTERNAL PARTS OF CELL. USE 3M MASK 9908. MASK PROTECTS UP
TO 0.5MG/M3 MERCURY VAPOR.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:AVOID HEAT OR WATER. DO NOT SHORT
CIRCUIT, CHARGE, OR OPEN THE BATTERY CELLS.
Other Precautions:DOT HAS CLASSIFIED THE AX-9/AX-15 AS FSC 6135 DRY
BATTERY. DOT LABEL, MARKING OR PLACARD NOT REQUIRED IN
TRANSPORTATION OF THE BATTERIES.
Exposure Controls
Respiratory Protection:NONE REQUIRED UNDER PROPER USE.
Ventilation:GENERAL WORKPLACE VENTILATION IS ADEQUATE.
Protective Gloves:NONE REQUIRED UNDER PROPER USE.
Eye Protection:NONE REQUIRED UNDER PROPER USE.
Other Protective Equipment:NONE REQUIRED UNDER PROPER USE.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
ALEXANDER MFG. CO CONSIDERS THE AX-9/AX-15 BATTERIES/CELLS AN ARTICLE
AS DEFINED IN 29 CFR 1910.1200 SECTION (C). UNDER NORMAL USE, IT
DOES NOT RELEASE OR OTHERWISE RESULT IN EXPOSURE TO A HAZARDOUS C
HEMICAL UNDER CONDITIONS OF INTENDED USE.
Chemical Properties
HCC:N1
Boiling Pt:B.P. Text:212F,100C
Spec Gravity:1
Solubility in Water:NEGLIGIBLE
Appearance and Odor:CYLINDRICAL BATTERY 1.5 IN. IN DIAMETER BY 2 IN.
LONG WITH 2 FLAT CONTACTS.
Stability
Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:HEATING ABOVE 160F, CHARGING, WATER.
Hazardous Decomposition Products:MANGANESE, MERCURY AND ZINC OXIDE.
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.